1.What are piers and explain about. Explain loads considered for calculating the total design force?Piers are structural elements typically used in construction to support loads from a bridge, building, or other elevated structure. They are vertical or near-vertical columns or posts that transfer the weight of the…
Nitin Prabhakar Arolkar
updated on 27 Aug 2024
1.What are piers and explain about. Explain loads considered for calculating the total design force?
Piers are structural elements typically used in construction to support loads from a bridge, building, or other elevated structure. They are vertical or near-vertical columns or posts that transfer the weight of the structure above them to a foundation or the ground below. Piers come in various forms and materials, including concrete piers, steel piers, wooden piers, and more, depending on the specific application and structural requirements.
The design of piers is critical in ensuring the safety and stability of the entire structure they support. To calculate the total design force on a pier, various loads and factors must be considered. These loads and factors include:
Dead Load (DL): This is the weight of the structure itself, including all permanent components such as beams, columns, walls, and floors. Dead load is relatively constant and does not change over time unless there are modifications to the structure.
Live Load (LL): Live load refers to the transient or variable loads that the structure may experience during its intended use. For example, in a building, this could include occupants, furniture, equipment, and other temporary loads. In the case of a bridge, it might involve the weight of vehicles and pedestrians.
Wind Load (WL): Wind can exert lateral forces on a structure, and designers must consider wind loads to ensure stability. The wind load depends on factors such as the wind speed, the shape and size of the structure, and its location.
Seismic Load (SL): In earthquake-prone regions, piers must be designed to withstand seismic forces. The seismic load depends on the local seismic activity, the soil conditions, and the characteristics of the structure.
Temperature Effects: Changes in temperature can cause expansion and contraction of materials, leading to thermal loads. These temperature-induced stresses need to be considered in the pier's design.
Soil Bearing Capacity: The capacity of the soil or foundation material to support the load is crucial. Engineers perform soil tests to determine the bearing capacity, which influences the design of the pier's foundation.
Water Loads: For piers located in water bodies, buoyancy forces and wave loads need to be considered to prevent the structure from floating or experiencing excessive stress.
Settlement and Movement: Settlement of the pier or the soil beneath it over time must be taken into account. Piers should be designed to accommodate such movements without compromising stability.
Special Considerations: Depending on the specific application, other factors such as ice loads (for piers in cold climates), marine corrosion (for piers in saltwater environments), and dynamic forces (e.g., from machinery) may also be considered.
2.Explain about the DL, SIDL & LL considered for designing a pier of a metro viaduct? Also, what grade of cement is being used in the construction of piers
When designing piers for a metro viaduct, we consider various loads, including Dead Load (DL), Superimposed Dead Load (SIDL), and Live Load (LL). These loads play a crucial role in determining the design and structural requirements for the piers. Additionally, the grade of cement used in the construction of piers is typically specified to meet the necessary strength and durability requirements.
Dead Load (DL):
Superimposed Dead Load (SIDL):
Live Load (LL):
The choice of cement grade for the construction of piers depends on the specific design requirements, local building codes, and engineering standards. In general, for structural elements like piers, engineers commonly use ordinary Portland cement (OPC) or Portland Pozzolana Cement (PPC). The choice between OPC and PPC depends on factors such as the project location, environmental conditions, and specific performance requirements.
OPC is known for its high compressive strength and is suitable for projects where strength is a primary concern. PPC, on the other hand, contains pozzolanic materials (such as fly ash or silica fume) that enhance durability and reduce the risk of cracks. PPC is often preferred in areas with aggressive environmental conditions, as it offers better resistance to chemical attacks and sulfate exposure.
The specific grade (e.g., 33, 43, 53) of cement chosen for pier construction would depend on the engineering specifications and structural requirements of the metro viaduct project, as well as any regional or local building codes or standards that must be followed.
3.Explain about the Braking & Traction effect and loads considered for designing a pier of a metro viaduct
In the design of piers for a metro viaduct, we need to consider the effects of braking, traction, and various loads associated with the operation of the metro system. These effects are critical for ensuring the safety and stability of the viaduct structure. Let's explain these aspects in more detail:
Braking and Traction Effects:
Braking Effect: When a metro train decelerates or comes to a stop, it applies brakes to reduce its speed. The braking force generates a horizontal load on the viaduct structure. This load can be significant, especially during rush hours or emergency braking situations.
Traction Effect: On the other hand, when a metro train accelerates, it exerts a forward traction force to propel itself. This traction force also generates a horizontal load, but in the opposite direction of braking.
Both braking and traction effects are dynamic and result in horizontal forces that act on the piers and the viaduct structure. These forces can induce lateral movement and stress in the piers, which must be accounted for in the design.
Dynamic Live Load (LL):
Wind Loads:
Seismic Loads (if applicable):
Temperature Effects:
Corrosion Protection:
Designing piers for a metro viaduct involves a comprehensive structural analysis that considers all these loads and effects to ensure the safety, durability, and functionality of the entire system.
4.Explain about the Centrifugal force & Wind load considered for designing a pier of a metro viaduct
In the design of piers for a metro viaduct, engineers consider several external forces and loads, including centrifugal forces and wind loads. These forces play a crucial role in ensuring the structural integrity and stability of the viaduct. Let us how centrifugal force and wind load are considered in the design:
Centrifugal Force:
Wind Load:
To address centrifugal force and wind load in the design of metro viaduct piers, we follow established engineering codes, standards, and guidelines specific to the region where the viaduct is being constructed. These standards provide criteria for calculating and accommodating these loads in the structural design process.
In summary, centrifugal force arising from train movement through curves and wind load due to environmental conditions are important considerations in the design of piers for metro viaducts. Accurate calculations and simulations help engineers ensure the viaduct's stability, safety, and performance under these dynamic and environmental influences.
5.Explain about the Earthquake load & how the loadings are calculated as per code. Explain the three types where the seismic loads are considered.
Earthquake loads, also known as seismic loads, are critical considerations in the design of structures like piers for a metro viaduct, particularly in areas prone to seismic activity. Earthquakes exert dynamic forces on structures, and engineers must account for these loads to ensure the safety and integrity of the viaduct. Seismic loadings are calculated based on specific codes and standards, and they can be categorized into three main types:
Static Equivalent Method:
Response Spectrum Method:
Time History Analysis:
The specific method chosen for calculating seismic loads depends on the complexity of the structure, the site's seismic hazard, and local building codes and standards.
6.Explain about the LWR forces & Derailment loads how the loadings are calculated as per code.
"LWR forces" and "derailment loads" refer to important considerations in the design of railway infrastructure, including tracks, bridges, and piers, to ensure safety and structural integrity.
These concepts and how the loadings are calculated as per relevant codes and standards are as follows:
LWR (Longitudinal Wheel- Rail) Forces:
These standards provide equations and methodologies for determining the dynamic loadings on tracks, bridges, and supporting structures.
Derailment Loads:
7.Explain the design combinations of the all the loads considered in a metro design through which we attain the factored BM from unfactored bending moments.
In the design of structures for metro systems, including piers, bridges, and other components, engineers consider a combination of loads to ensure the safety and structural integrity of the entire system. These loads are factored to account for uncertainties and variations, and the process involves several steps to obtain factored bending moments (BM) from unfactored bending moments. Here's an overview of the design combinations and the factoring process:
Unfactored Loads:
Load Combinations:
Factored Loads:
Structural Analysis:
Design Criteria:
Design Adjustments:
The combination of loads and the factoring process are essential in metro system design to ensure that structures can safely withstand the various forces and conditions they may encounter during their service life. The goal is to design structures that provide reliable and safe transportation for passengers while maintaining structural integrity and longevity.
8.Explain the reason behind the factored load of SIDL is higher than the factored load of DL in a design.
The factored load of SIDL (Superimposed Dead Load) being higher than the factored load of DL (Dead Load) in a structural design is a result of engineering safety practices and is based on the principle of accounting for worst-case scenarios and uncertainties. This approach helps ensure that structures are designed with an appropriate margin of safety to account for variations in loading and other factors. Here's why the factored load of SIDL is often higher than that of DL:
Nature of Loads:
Safety and Uncertainty Factors:
Conservative Design:
In summary, the factored load of SIDL is higher than the factored load of DL to ensure that structures are designed to withstand a wide range of loading conditions, including those associated with temporary or variable loads. This approach aligns with the fundamental engineering principle of prioritizing safety and reliability in structural design.
9.What are the basic design parameters considered for a RCC pier cap.
Reinforced Concrete (RCC) pier caps are critical structural components in bridges and viaducts, providing support and stability to the piers that carry the load of the superstructure. The design of RCC pier caps involves several basic parameters and considerations to ensure their structural integrity and functionality. Here are some of the fundamental design parameters considered for an RCC pier cap:
Loadings and Forces:
Dimensions and Geometry:
Material Properties:
Reinforcement Layout:
Load Distribution:
Durability and Exposure Conditions:
Construction Methods:
Serviceability and Deflection Limits:
Code Compliance:
Seismic Considerations (if applicable):
Overall, the design parameters for an RCC pier cap are tailored to the specific requirements of the project, taking into account structural, environmental, and construction-related factors. These parameters are used to develop detailed design drawings and specifications that guide the construction of the pier cap to meet the desired performance and safety standards.
10.Explain the reinforcement detailing from the result extraction in longitudinal & sectional views of a viaduct.
Reinforcement detailing is a crucial step in the design and construction of viaducts, ensuring that the reinforcing steel (rebar) is correctly placed within the structure to provide the required strength and durability. Detailing involves specifying the quantity, size, spacing, and placement of rebar in both the longitudinal and sectional views of the viaduct.Explanation of reinforcement detailing in these views are as follows:
Longitudinal View:
In the longitudinal view of the viaduct, we are looking at the structure from the side, along its length. The detailing in this view includes:
Main Reinforcement Bars: These are the primary horizontal bars that run parallel to the length of the viaduct. They provide resistance to bending and shear forces. The detailing specifies the diameter, spacing, and arrangement of these bars along the length of the viaduct.
Stirrups or Ties: Stirrups (also known as ties) are vertical or inclined bars that encircle the main reinforcement bars. They help confine the concrete and provide resistance against shear forces and diagonal cracking. The detailing specifies the diameter, spacing, and height at which stirrups are placed.
Transverse Reinforcement: In some cases, additional transverse reinforcement may be required, especially at locations with concentrated loads or where the structure experiences lateral forces. This reinforcement helps distribute loads and control cracking. The detailing provides the quantity, size, and placement of transverse bars.
Development and Lap Lengths: The detailing also specifies the lengths at which bars are developed (anchored) at the ends of structural members and where laps (overlapping) occur. This ensures that the bars are properly connected to maintain structural integrity.
Clear Cover: Clear cover refers to the distance between the surface of the concrete and the nearest reinforcement bar. The detailing specifies the required clear cover to protect the rebar from environmental factors and corrosion.
Sectional View:
In the sectional view, we are looking at a cross-section of the viaduct, typically at specific locations like piers, abutments, or beam-column connections. The detailing in this view includes:
Bend and Hook Details: At locations where rebar needs to be bent or hooked to fit the geometry of the viaduct or to provide anchorage, the detailing provides information on the bend radius, hook length, and shape of the bends or hooks.
Splice Details: When rebar cannot be continuous and needs to be spliced together, the detailing specifies the splice length, type of splice (e.g., mechanical couplers or lap splices), and location of the splice within the structural element.
Special Details: Special reinforcement details may be required at specific locations, such as around openings, expansion joints, or areas with high-stress concentrations. These details are customized to address the unique requirements of these areas.
Concrete Encasement: In some cases, rebar may need to be fully encased in concrete for added protection or to meet specific design criteria. The detailing specifies the thickness and extent of concrete encasement.
Corrosion Protection: If corrosion protection measures like epoxy-coated rebar or concrete cover over rebar are required, the detailing provides instructions on their application.
Reinforcement detailing is typically provided in construction drawings and specifications, and it serves as a critical guide for contractors to correctly place rebar during construction. Proper reinforcement detailing ensures that the viaduct meets structural design requirements, withstands the intended loads, and maintains its long-term durability. Compliance with engineering standards and local building codes is essential when detailing reinforcement in viaducts and other structures.
Leave a comment
Thanks for choosing to leave a comment. Please keep in mind that all the comments are moderated as per our comment policy, and your email will not be published for privacy reasons. Please leave a personal & meaningful conversation.
Other comments...
Project 1_Comparative study of different storey buildings for Seismic forces
1. Factors influencing the Natural Period of a building:Effect of stiffness on T: Compare fundamental natural periods of buildings E & F as well as G & H. Why is there a marginal or significant difference in the fundamental natural periods? Increase in the column size increases both stiffness and mass…
01 Nov 2024 06:23 PM IST
Project 2_Design & Analysis of a Hostel building at Guwahati, Assam
In this project, participants will get to experience the entire design process from modelling, analysis, design, and preparation of construction drawings. The architectural drawings of a G+3 RCC building is provided. The following information on the building is to be used:Location – Guwahati, AssamFunction – Hostel block…
30 Oct 2024 10:55 AM IST
Foundation Design using SAFE
1.Model the isolated footing provided in week 11 challenge on SAFE. Analyze and design it to verify the size, depth and steel provided as per calculations.AIM:- To model the isolated footing by using SAFE and to analyze and to design it to verify the size, depth and calculation of steel providedINTRODUCTION:-…
30 Oct 2024 10:52 AM IST
Design of Shallow Foundation (Isolated Footings)
Q.1 Design of Foundation in STAAD Foundation.(i) AIM: Using STAAD Foundation designing Isolated FootingGiven :- Column = 300 mm x 450 mm.Axial load = 1500 kNMu = 150 kNm.Assume that the moment is reversible.The safe bearing capacity of the soil = 200 KN/m^2.Depth = 1 m from ground level.M…
30 Oct 2024 10:47 AM IST
Related Courses
127 Hours of Content
Skill-Lync offers industry relevant advanced engineering courses for engineering students by partnering with industry experts.
© 2024 Skill-Lync Inc. All Rights Reserved.