Question 1:The building shown, 20 × 35 m in plan, has columns on a 5 × 5 m grid and shear walls (with dimensions shown in m, 250 mm in thickness) in three alternative arrangements, (a), (b), (c), all with the same total cross-sectional area of the shear walls. Compare the three alternatives, taking into account…
Akash Dhathombe
updated on 12 Feb 2023
Question 1:
The building shown, 20 × 35 m in plan, has columns on a 5 × 5 m grid and shear walls (with dimensions shown in m, 250 mm in thickness) in three alternative arrangements, (a), (b), (c), all with the same total cross-sectional area of the shear walls. Compare the three alternatives, taking into account the restraint of floor shrinkage, the lateral stiffness and the torsional one with respect to the vertical axis, the vertical reinforcement required for the same total flexural capacity at the base, the static eccentricity, the system’s redundancy, foundation systems, architectural constraints etc.
Question 2:
Discuss the suitability for earthquake resistance of the moment resisting framing plan of a three-storey building depicted here (cross-sectional dimensions in cm), the eccentricity of the centre of mass (as centroid of floor plan) to the centre of stiffness (from the moments of inertia of the columns) are shown. Suggest an alternative. Also, is there torsional flexibility? Are the two fundamental translational modes of vibration larger than the fundamental torsional mode of vibration. Discuss qualitatively.
Issues in the given Framing plan:
Indirect lateral load Transfer in X and Y directions - The beams are connecting to another beams which is ineffective during lateral load transfer. In such conditions, the primary beam is prone to shear failure.
Issues in the given Framing plan:
Eccentricity - The longer the distance between center of mass and center of stiffness, the higher torsional moment of the building. As per the given plan eccentricity, the building is subjected to higher torsional moment (Torsional flexibility) in both X and Y directions.
Issues in the given Framing plan:
Strong beam Weak Column possibility
- The size of columns majorly mentioned as 25 cm x 25 cm. But all the beams have much deeper section (50cm). Inertia of beam is visually higher than column. If the column reinforcement is adequately greater than that of beams, we are okay and since we do not have the reinforcement detail, this is doubtful. It is recommended to have slight bigger sizes for column.
Alternate Scheme :
Question 3:
A multi-storey building with basement, with a quadrilateral (non symmetrical floor plan) plan as, has interior columns in an irregular (not in a grid) pattern in plan that serves architectural and functional considerations. Partition walls and interior beams supporting the slab have different layout in different stories. However, there is no constraint to the type, location and size of the lateral force resisting components and sub-systems on the perimeter. Proposals are to be made and justified for the choice of the lateral-load-resisting system and its foundation.
Observations in the given Framing plan:
Floor plan - The floor plan of building is not either uniform or symmetric. So naturally any lateral load induced in the floor will not have 100% influence in same direction. Definitely a Special lateral load resisting system for these torsional moments should be accommodated.
Random Internal columns - Since the internal columns are random, they are unable to transfer lateral loads efficiently and can not achieve desirable building response. So we have to assume and design those columns for only gravity loads.
Floor to floor variations in Partition walls and Beams - Partition walls provide an important mass control in a building and beams play key role in shear transfer from floor to beam. All these elements are not in order. So heavy distortion and distribution of lateral loads will happen.
Suggestion on the Lateral load system & Its foundation:
Heavy torsional forces should be controlled by respective lateral load system. So "Corner Shear walls" are suggested.
The proportion of floor area is greater on the left side than the right side (Irregular quadrilateral). So Corner shear walls on the left side should be heavier than the right.
Corner Shear walls shall preferably be supported over a box foundation. Shear walls should be connected by Link beams to transfer shear from one to the other.
The internal columns shall be supported by isolated footings. Those isolated footings can be connected with Shear walls through Tie beams.
Superstructure Sub Structure
Leave a comment
Thanks for choosing to leave a comment. Please keep in mind that all the comments are moderated as per our comment policy, and your email will not be published for privacy reasons. Please leave a personal & meaningful conversation.
Other comments...
Reinforcement Detailing of Beams from ETABS output
Challenge 7 – Detailed design of concrete buildings -1 Detail design of beams in Etabs 2018.The ETABS file for a G+4 building is provided. Run the analysis and design the RCC Moment ResistingFrame. The following challenge deals specifically with two continuous beams in the 1st floor. 1)…
16 Apr 2023 05:06 PM IST
Project 1_Comparative study of different storey buildings for Seismic forces
Project-1 Comparative Study of Different Story Buildings for Seismic Forces Factors influencing the dynamic characteristics of a building :- Buildings oscillate during earthquake shaking. The oscillation causes inertia force to be induced in the building. The intensity and duration of oscillation, and the amount…
13 Apr 2023 08:55 AM IST
Modelling of 25 storey building with the specified properties using ETABS
AIM: To model a 25 storey building on ETABS with structural properties as specified below. INTRODUCTION: ETABS is an engineering software product that caters to multi-story building analysis and design. Modeling tools and templates, code-based load prescriptions, analysis methods and solution techniques,…
09 Apr 2023 01:43 PM IST
Conceptual design of a building with columns and shear walls
Question 1:The building shown, 20 × 35 m in plan, has columns on a 5 × 5 m grid and shear walls (with dimensions shown in m, 250 mm in thickness) in three alternative arrangements, (a), (b), (c), all with the same total cross-sectional area of the shear walls. Compare the three alternatives, taking into account…
12 Feb 2023 02:03 AM IST
Related Courses
0 Hours of Content
Skill-Lync offers industry relevant advanced engineering courses for engineering students by partnering with industry experts.
© 2025 Skill-Lync Inc. All Rights Reserved.